SIMULASI PENGARUH LUAS PERMUKAAN ELEKTRODA TERHADAP TEGANGAN DAN KONSENTRASI PERMUKAAN ELEKTRODA PADA LEAD ACID REDOX FLOW BATTERY

  • Ghufron M
  • Hadila S
  • Felindia E
  • et al.
N/ACitations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

Energy storage systems (ESS) with large storage capabilities, easy made, and low cost are in high demand. Dynamic lead acid battery (DLAB) as a breakthrough design compared conventional lead acid batteries offers a solution to these problems. Two Dimensional (2D) DLAB simulations with surface area variations of 8 cm2, 12 cm2, 16 cm2 and 20 cm2 were successfully build using the principle of tertiary current distribution and Nerst-Planck Interface. The results for one cycle charge-discharge test showed that the increase in surface area succeeded in increasing the final charging voltage with a value of 2.16 V; 2, 21 V; 2.30 V and 2.32 V and increase the initial discharging voltage by a value of 1.58 V; 1.59 V; 1.60 V and 1.62 V respectively but did not affect the electrode surface concentration. Dynamic lead acid battery has high energy efficiency of 70.6% -71.5%.

Cite

CITATION STYLE

APA

Ghufron, M., Hadila, S., Felindia, E., Syaharani, N., Kumara, S. P. P., Hidayah, I. F., … Pranata, K. B. (2021). SIMULASI PENGARUH LUAS PERMUKAAN ELEKTRODA TERHADAP TEGANGAN DAN KONSENTRASI PERMUKAAN ELEKTRODA PADA LEAD ACID REDOX FLOW BATTERY. ROTOR, 14(1), 12. https://doi.org/10.19184/rotor.v14i1.23850

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley