The Membrane Fouling Simulator as a new tool for biofouling control of spiral-wound membranes

77Citations
Citations of this article
69Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Studies with a new tool - the Membrane Fouling Simulator (MFS) - illustrate that the MFS can be used to quantify and characterize fouling. Using the MFS, fouling can be monitored by (1) operational parameters like pressure drop, (2) non-destructive (visual, microscopic) observations using the sight glass and (3) analysis of coupons sampled from the membrane sheet in the MFS. The small scale of the MFS makes it easy to handle and requires small amounts of water and chemicals, enhancing the possibility to test several MFS units in parallel. A comparison study of the MFS and spiral-wound membrane modules showed the same fouling. The MFS is representative for spiral membrane elements, indicating that the MFS is suitable to study and monitor biofouling. © 2006 Elsevier B.V. All rights reserved.

Cite

CITATION STYLE

APA

Vrouwenvelder, J. S., Bakker, S. M., Wessels, L. P., & van Paassen, J. A. M. (2007). The Membrane Fouling Simulator as a new tool for biofouling control of spiral-wound membranes. Desalination, 204(1-3 SPEC. ISS.), 170–174. https://doi.org/10.1016/j.desal.2006.04.028