Abstract
Carbon contamination of optics is a serious issue in all soft X-ray beamlines because it decreases the quality of experimental data, such as near-edge X-ray absorption fine structure, resonant photoemission and resonant soft X-ray emission spectra in the carbon K-edge region. Here an in situ method involving the use of oxygen activated by zeroth-order synchrotron radiation was used to clean the optics in a vacuum ultraviolet and soft X-ray undulator beamline, BL-13A at the Photon Factory in Tsukuba, Japan. The carbon contamination of the optics was removed by exposing them to oxygen at a pressure of 10 -1-10 -4 Pa for 17-20 h and simultaneously irradiating them with zeroth-order synchrotron radiation. After the cleaning, the decrease in the photon intensity in the carbon K-edge region reduced to 2-5%. The base pressure of the beamline recovered to 10 -7-10 -8 Pa in one day without baking. The beamline can be used without additional commissioning. © 2012 International Union of Crystallography Printed in Singapore - all rights reserved.
Author supplied keywords
Cite
CITATION STYLE
Toyoshima, A., Kikuchi, T., Tanaka, H., Adachi, J. I., Mase, K., & Amemiya, K. (2012). In situ removal of carbon contamination from optics in a vacuum ultraviolet and soft X-ray undulator beamline using oxygen activated by zeroth-order synchrotron radiation. Journal of Synchrotron Radiation, 19(5), 722–727. https://doi.org/10.1107/S0909049512024971