Abstract
Membrane-based vacuum dehumidification technology is currently being actively studied. In most studies, the performance of the membrane-based systems is evaluated under the assumption that the membrane can achieve ideal separation, which results in ideal coefficient of performance (COP) values. However, the performance factors for membranes vary depending on the experimental conditions and measurement methods. Therefore, relevant values can only be calculated if the data are measured in an environment close to that of the application conditions. The cup measurement method is a simple method to measure the permeability, however, there are limitations regarding adding variables during the experiment. To overcome these limitations, a new experimental device was constructed that combines pressurized cell with the cup method. Using the device, the performance of polyethylene-amide-bonded dense membranes was evaluated under conditions where absolute pressure differentials occurred before and after the membrane, such as in air conditioner dehumidification systems.
Author supplied keywords
Cite
CITATION STYLE
Lee, J., Kim, H. S., Ku, D., Lim, J., Jung, M., Kim, S., … Seo, Y. S. (2021). Experimental study on the water selective dense membrane under an absolute pressure difference with simplified test method. Applied Sciences (Switzerland), 11(4), 1–16. https://doi.org/10.3390/app11041710
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.