A change in pituitary magnetic resonance imaging protocol detects ACTH-secreting tumours in patients with previously negative results

44Citations
Citations of this article
50Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective While detection of pituitary tumours with magnetic resonance imaging (MRI) may reduce diagnostic costs and improve surgical outcomes for patients with Cushing's disease, the optimal T1-weighted spin-echo (SE) MRI protocol remains unknown. We hypothesized that specific MR scanning parameters influence detection of corticotropinomas. Design and patients Between December 1997 and November 2004, 21 of 84 consecutive patients with Cushing's disease had a falsely negative initial pituitary MRI study and a lesion identified subsequently at the National Institutes of Health Clinical Center. This study retrospectively reviewed and compared technical parameters used for the two pituitary T1-weighted SE MRIs in 18 patients with available scans. Measurements Repetition time (TR)/echo times (TE), field of view (FOV), matrix size, magnetic field strength, slice thickness, use of gadolinium contrast and the time interval between studies were recorded. Results The MRI interscan interval was 5·4 ± 1·1 months. All scans used gadolinium, matrix sizes were similar and nearly all had 3-mm thick slices. Parameters that differed between the NIH- and externally performed scans were: TR (400 ms vs. 492 ± 19 ms, P = 0·0002); TE (10·3 ± 0·5 vs. 17·2 ± 1·2 ms, P = 0·0003); FOV (12 × 12 cm vs.17 ± 0·6 × 18 ± 0·7 cm, P < 0·0001). Immunohistochemistry of tumours resected at transsphenoidal surgery confirmed all to be corticotropinomas. Conclusions Not all 'T1-weighted SE' scans are equally accurate. MRI technique, particularly FOV and TR/TE value, influences results. We recommend that endocrinologists consider pituitary MRI parameters when interpreting the results. © Published 2010. This article is a US Government work and is in the public domain in the USA.

Cite

CITATION STYLE

APA

Chowdhury, I. N., Sinaii, N., Oldfield, E. H., Patronas, N., & Nieman, L. K. (2010). A change in pituitary magnetic resonance imaging protocol detects ACTH-secreting tumours in patients with previously negative results. Clinical Endocrinology, 72(4), 502–506. https://doi.org/10.1111/j.1365-2265.2009.03646.x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley