Predictors of initiating rapid-acting insulin analog using vial/syringe, prefilled pen, and reusable pen devices in patients with type 2 diabetes

4Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Limited data are available on the predictors of insulin delivery device choice. This study assessed the patient- and health-care-system-related factors that predict the initiation of one rapid-acting insulin analog (RAIA) delivery system over another. Methods: A retrospective analysis using a claims database (January 1, 2007, through March 31, 2009) was conducted. Patients were required to be diagnosed with type 2 diabetes mellitus, and have ≥12 months of continuous eligibility prior to their first prescription of a RAIA on or after January 1, 2008. The three cohorts in the study were vial/syringe (n = 6820), prefilled pen (n = 5840), and reusable pen (n = 2052). Multiple factors were examined using stepwise logistic regression. Results: Factors that increased the likelihood of initiating RAIA using prefilled pen versus vial/syringe included endocrinologist visit [odds ratio (OR) = 3.13, 95% confidence interval (CI) = 2.56, 3.82], prior basal insulin use with pen (OR = 4.85, 95% CI = 4.21, 5.59), and use of ≥1 oral antihyperglycemic agents (OR = 1.32, 95% CI = 1.20, 1.45). Factors that decreased the likelihood included inpatient admission (OR = 0.76, 95% CI = 0.70, 0.83), nursing home visit (OR = 0.22, 95% CI = 0.18, 0.27), and obesity (OR = 0.67, 95% CI = 0.53, 0.83). There were fewer differences between prefilled and reusable pen initiators. Factors that increased the likelihood of initiating with prefilled versus reusable pen included endocrinologist visit (OR = 1.87, CI = 1.50, 2.34) and inpatient admission (OR = 1.46, 95% CI = 1.30, 1.64). Conclusion: Significant differences in predictors were observed between prefilled pen and vial/syringe initiators. The differences were fewer between prefilled and reusable pen initiators. These differences should be taken into consideration when evaluating outcomes associated with specific insulin delivery systems. © Diabetes Technology Society.

Cite

CITATION STYLE

APA

Lee, L. J., Anderson, J., Foster, S. A., Corrigan, S. M., Smith, D. M., & Curkendall, S. (2010). Predictors of initiating rapid-acting insulin analog using vial/syringe, prefilled pen, and reusable pen devices in patients with type 2 diabetes. In Journal of Diabetes Science and Technology (Vol. 4, pp. 547–557). SAGE Publications Inc. https://doi.org/10.1177/193229681000400307

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free