Comparison of corneal power and astigmatism between simulated keratometry, true net power, and total corneal refractive power before and after SMILE surgery

29Citations
Citations of this article
38Readers
Mendeley users who have this article in their library.

Abstract

Purpose. To compare the mean corneal power (Km) and total astigmatism (Ka) estimated by three methods: Simulated keratometry (simK), true net power (TNP), and total corneal refractive power (TCRP) before and after femtosecond laser small incision lenticule extraction (SMILE) surgery. Methods. A retrospective, cross-sectional study. SimK, TNP, and TCRP from a Scheimpflug analyzer were obtained from 144 patients before and 6 months after SMILE surgery. Km and Ka were recorded as the mean of individual paracentral rings of 1.0 to 8.0 mm (R1 to R8). The surgically induced changes in Km (delta-simK, delta-TNP, and delta-TCRP) and Ka (delta-simKa, delta-TNPa, and delta-TCRPa) were compared to the changes in spherical equivalent of the cycloplegic refraction (delta-SE) and astigmatism (delta-RA). Results. Preoperatively, astigmatism values were greatest with simKa from R1 to R5 and greatest with TCRPa from R6 to R8. Astigmatism values were smallest with TNPa from R1 to R7. Postoperatively, astigmatism values were greatest with simKa from R1 to R5 and greatest with TCRPa from R6 to R8. Delta-TCRP3 and Delta-TCRP4 matched delta-SE most closely, and delta-TCRPa3 matched delta-RA most closely. Conclusions. TCRP proved to be the most accurate method in estimating corneal power and astigmatism both before and after SMILE surgery.

References Powered by Scopus

STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT

42339Citations
N/AReaders
Get full text

Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: Results of a 6 month prospective study

725Citations
N/AReaders
Get full text

Astigmatism analysis by the Alpins method

495Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Comparison of wavefront-guided femtosecond LASIK and optimized SMILE for correction of moderate-to-high astigmatism

26Citations
N/AReaders
Get full text

Predictability of intraocular lens power calculation after small-incision lenticule extraction for myopia

19Citations
N/AReaders
Get full text

Twelve-month outcomes of a new refractive lenticular extraction procedure

16Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Qian, Y., Liu, Y., Zhou, X., & Naidu, R. K. (2017). Comparison of corneal power and astigmatism between simulated keratometry, true net power, and total corneal refractive power before and after SMILE surgery. Journal of Ophthalmology, 2017. https://doi.org/10.1155/2017/9659481

Readers over time

‘17‘18‘19‘20‘21‘22‘23‘24036912

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 12

71%

Professor / Associate Prof. 2

12%

Researcher 2

12%

Lecturer / Post doc 1

6%

Readers' Discipline

Tooltip

Medicine and Dentistry 18

82%

Engineering 3

14%

Agricultural and Biological Sciences 1

5%

Save time finding and organizing research with Mendeley

Sign up for free
0