The P̄ANDA focussing-lightguide disc DIRC

7Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.
Get full text

Abstract

P̄ANDA will be a fixed target experiment internal to the HESR antiproton storage ring at the future FAIR complex. The P̄ANDA detector requires excellent particle-identification capabilities in order to achieve its scientific potential. Cherenkov counters employing the DIRC principle were chosen as PID detectors for the Target Spectrometer. The proposed Focussing-Lightguide Disc DIRC will cover the forward part of the Target Spectrometer acceptance in the angular range between 5° and 22°. Its design includes a novel approach to mitigate dispersion effects in the solid radiator of a DIRC counter using optical elements. The dispersion correction will enable the Focussing-Lightguide Disc DIRC to provide pion-kaon identification for momenta well above 3.5 GeV/c. © 2009 IOP Publishing Ltd and SISSA.

Cite

CITATION STYLE

APA

Cowie, E., Föhl, K., Glazier, D., Hill, G., Hoek, M., Kaiser, R., … Seitz, B. (2009). The P̄ANDA focussing-lightguide disc DIRC. Journal of Instrumentation, 4(9). https://doi.org/10.1088/1748-0221/4/09/P09006