The Microfabricated Alkali Vapor Cell with High Hermeticity for Chip-Scale Atomic Clock

15Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

Abstract

Herein, a microfabricated millimeter-level vapor alkali cell with a high hermeticity is fabricated through a wet etching and single-chip anodic bonding process. The vapor cell, containing Rb and N2, was investigated in a coherent population trapping (CPT) setup for the application of a chip-scale atomic clock (CSAC). The contrast of CPT resonance is up to 1.1% within the only 1 mm length of light interacting with atom. The effects of some critical external parameters on the CPT resonance, such as laser intensity, cell temperature, and buffer gas pressure, are thoroughly studied and optimized. The improved microfabricated vapor cell also exhibited great potential for other chip-scale atomic devices.

Cite

CITATION STYLE

APA

Jia, S., Jiang, Z., Jiao, B., Liu, X., Pan, Y., Song, Z., & Qu, J. (2022). The Microfabricated Alkali Vapor Cell with High Hermeticity for Chip-Scale Atomic Clock. Applied Sciences (Switzerland), 12(1). https://doi.org/10.3390/app12010436