Extensive bullous complication associated with intermittent pneumatic compression

10Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

Intermittent pneumatic compression (IPC) device is an effective method to prevent deep vein thrombosis. This method has been known to be safe with very low rate of complications compared to medical thromboprophylaxis. Therefore, this modality has been used widely in patients who underwent a hip fracture surgery. We report a patient who developed extensive bullae, a potentially serious skin complication, beneath the leg sleeves during the use of IPC device after hip fracture surgery. © Yonsei University College of Medicine 2013.

Cite

CITATION STYLE

APA

Won, S. H., Lee, Y. K., Suh, Y. S., & Koo, K. H. (2013). Extensive bullous complication associated with intermittent pneumatic compression. Yonsei Medical Journal, 54(3), 801–802. https://doi.org/10.3349/ymj.2013.54.3.801