Dynamic hyperinflation and intrinsic positive end-expiratory pressure in ARDS patients

9Citations
Citations of this article
34Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: In ARDS patients, changes in respiratory mechanical properties and ventilatory settings can cause incomplete lung deflation at end-expiration. Both can promote dynamic hyperinflation and intrinsic positive end-expiratory pressure (PEEP). The aim of this study was to investigate, in a large population of ARDS patients, the presence of intrinsic PEEP, possible associated factors (patients' characteristics and ventilator settings), and the effects of two different external PEEP levels on the intrinsic PEEP. Methods: We made a secondary analysis of published data. Patients were ventilated with a tidal volume of 6-8 mL/kg of predicted body weight, sedated, and paralyzed. After a recruitment maneuver, a PEEP trial was run at 5 and 15 cmH2O, and partitioned mechanics measurements were collected after 20 min of stabilization. Lung computed tomography scans were taken at 5 and 45 cmH2O. Patients were classified into two groups according to whether or not they had intrinsic PEEP at the end of an expiratory pause. Results: We enrolled 217 sedated, paralyzed patients: 87 (40%) had intrinsic PEEP with a median of 1.1 [1.0-2.3] cmH2O at 5 cmH2O of PEEP. The intrinsic PEEP significantly decreased with higher PEEP (1.1 [1.0-2.3] vs 0.6 [0.0-1.0] cmH2O; p < 0.001). The applied tidal volume was significantly lower (480 [430-540] vs 520 [445-600] mL at 5 cmH2O of PEEP; 480 [430-540] vs 510 [430-590] mL at 15 cmH2O) in patients with intrinsic PEEP, while the respiratory rate was significantly higher (18 [15-20] vs 15 [13-19] bpm at 5 cmH2O of PEEP; 18 [15-20] vs 15 [13-19] bpm at 15 cmH2O). At both PEEP levels, the total airway resistance and compliance of the respiratory system were not different in patients with and without intrinsic PEEP. The total lung gas volume and lung recruitability were also not different between patients with and without intrinsic PEEP (respectively 961 [701-1535] vs 973 [659-1433] mL and 15 [0-32] % vs 22 [0-36] %). Conclusions: In sedated, paralyzed ARDS patients without a known obstructive disease, the amount of intrinsic PEEP during lung-protective ventilation is negligible and does not influence respiratory mechanical properties.

Cite

CITATION STYLE

APA

Coppola, S., Caccioppola, A., Froio, S., Ferrari, E., Gotti, M., Formenti, P., & Chiumello, D. (2019). Dynamic hyperinflation and intrinsic positive end-expiratory pressure in ARDS patients. Critical Care, 23(1). https://doi.org/10.1186/s13054-019-2611-6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free