Abstract
The article describes the case of a 47-year-old man presented with multiple sclerosis (MS) and diagnosed with hyperthyroidism with positive thyroid-specific autoantibodies. Topics discussed include results of some procedures performed on the patient including immunoassay based on streptavidin-biotin interaction and biotin interference with the test as the reason for discrepancies between the clinical presentation and laboratory findings of patients taking biotin.
Cite
CITATION STYLE
Köhler, V. F., Mann, U., & Mann, W. A. (2018). Biotin Interference in the Measurement of Thyroid Hormone. Deutsches Ärzteblatt International. https://doi.org/10.3238/arztebl.2018.0500