Survey of heat transfer mechanisms in a slurry bubble column

41Citations
Citations of this article
29Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Heat transfer mechanisms in the bulk and distributor regions of a slurry bubble column are investigated based on the measurements of local heat transfer in a 0.28 m diameter Plexiglas column. The gas, liquid and solid phases used are oil-free compressed air, tap water and 35 μm glass beads. The slurry concentration and superficial gas velocity are varied from 0 to 40 vol% and 0.05 to 0.30 m/s respectively. Measurements have been made with a fast response heat flux probe which provided local instantaneous heat transfer coefficients. The time-averaged heat transfer coefficients in the bulk region were on average about 50% higher than the distributor region of the column. The wall region heat transfer coefficients are well predicted by the correlation of Deckwer et al. (1980). Heat transfer mechanism in column centre can be adequately described by the consecutive film and surface renewal model.

Cite

CITATION STYLE

APA

Li, H., & Prakash, A. (2001). Survey of heat transfer mechanisms in a slurry bubble column. Canadian Journal of Chemical Engineering, 79(5), 717–725. https://doi.org/10.1002/cjce.5450790503

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free