A microscope for two-dimensional measurements of in vivo chlorophyll fluorescence kinetics using pulsed measuring radiation, continuous actinic radiation, and saturating flashes

48Citations
Citations of this article
28Readers
Mendeley users who have this article in their library.

Abstract

Transients of chlorophyll fluorescence in photosynthetic objects are often measured using short pulses of exciting radiation, which has recently been employed to capture kinetic images of fluorescence at the macroscopic level. Here we describe an instrument introducing this principle to recording of two dimensional fluorescence transients in microscopic objects. A modified fluorescence microscope is equipped with a CCD camera intensified by a micro-channel plate image amplifier. The microscopic field is irradiated simultaneously by three types of radiation: actinic radiation, saturating flashes, and pulsed measuring radiation. The measuring pulses are generated by a light-emitting diode and their duration is between 10 to 250 μs. The detection of fluorescence images (300×400 pixels, 8 bit) has a maximum time resolution of 40 ms and is gated in synchrony with the exciting pulses. This allows measuring on a background of a continuous actinic radiation up to irradiance that can elicit the maximal fluorescence yield (FM). On the other hand, the integral irradiance of the objects by the measuring radiation is very low, e. g., 0.08 μmol m-2 s-1 at 0.5 μm spatial resolution and 0.006 μmol m-2 s-1 at 4 μm spatial resolution. This allows a reliable recording of F0 even in very short time intervals (e. g., 5×80 ms). The software yields fluorescence kinetic curves for objects in user-selected areas as well as complete false-colour maps of the essential fluorescence kinetics parameters (FM, F0, FV, FV/FM, etc.) showing a two-dimensional distribution of their values. Several examples demonstrate that records of fluorescence kinetics can be obtained with a reasonable signal-to-noise ratio with all standard microscope objectives and with object sizes reaching from segments of leaf tissue to individual algal cells or chloroplasts.

Cite

CITATION STYLE

APA

Küpper, H., Šetlík, I., Trtílek, M., & Nedbal, L. (2001). A microscope for two-dimensional measurements of in vivo chlorophyll fluorescence kinetics using pulsed measuring radiation, continuous actinic radiation, and saturating flashes. In Photosynthetica (Vol. 38, pp. 553–570). Springer Netherlands. https://doi.org/10.1023/A:1012461407557

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free