Central venous pressure estimation from ultrasound assessment of the jugular venous pulse

26Citations
Citations of this article
42Readers
Mendeley users who have this article in their library.

Abstract

Objectives Acquiring central venous pressure (CVP), an important clinical parameter, requires an invasive procedure, which poses risk to patients. The aim of the study was to develop a noninvasive methodology for determining mean-CVP from ultrasound assessment of the jugular venous pulse. Methods In thirty-four adult patients (age = 60 ± 12 years; 10 males), CVP was measured using a central venous catheter, with internal jugular vein (IJV) cross-sectional area (CSA) variation along the cardiac beat acquired using ultrasound. The resultant CVP and IJV-CSA signals were synchronized with electrocardiogram (ECG) signals acquired from the patients. Autocorrelation signals were derived from the IJV-CSA signals using algorithms in R (open-source statistical software). The correlation r-values for successive lag intervals were extracted and used to build a linear regression model in which mean-CVP was the response variable and the lagging autocorrelation r-values and mean IJV-CSA, were the predictor variables. The optimum model was identified using the minimum AIC value and validated using 10-fold cross-validation. Results While the CVP and IJV-CSA signals were poorly correlated (mean r = -0.018, SD = 0.357) due to the IJV-CSA signal lagging behind the CVP signal, their autocorrelation counterparts were highly positively correlated (mean r = 0.725, SD = 0.215). Using the lagging autocorrelation r-values as predictors, mean-CVP was predicted with reasonable accuracy (r2 = 0.612), with a mean-absolute-error of 1.455 cmH2O, which rose to 2.436 cmH2O when cross-validation was performed. Conclusions Mean-CVP can be estimated non-invasively by using the lagged autocorrelation r-values of the IJV-CSA signal. This new methodology may have considerable potential as a clinical monitoring and diagnostic tool.

Cite

CITATION STYLE

APA

Zamboni, P., Malagoni, A. M., Menegatti, E., Ragazzi, R., Tavoni, V., Tessari, M., & Beggs, C. B. (2020). Central venous pressure estimation from ultrasound assessment of the jugular venous pulse. PLoS ONE, 15(10 October). https://doi.org/10.1371/journal.pone.0240057

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free