Experimental and Analytical Study of Slender Reinforced Concrete Shear Wall under Cyclic In-Plane Lateral Load

8Citations
Citations of this article
34Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

This study describes a slender reinforced concrete shear wall experimental test under in-plane cyclic lateral load, and the development of an analytical model which uses the fiber method approach to consider hysteretic nonlinear constitutive material models behavior. The shear wall tested had bending behavior, since the amount of longitudinal reinforcing bars produced weak bending capacity compared to the shear strength. The analytical model tries to represent global and local behavior of the wall, and its calibration is based on reaching experimental parameters like area enclosed and secant stiffness on every loop. After the analytical model was calibrated, the relation between some performance points and damage states observed during the test is studied.

Cite

CITATION STYLE

APA

Sosa, D., Arévalo, D., Mora, E. D., Correa, M. B., Albuja, D., & Gómez, C. (2017). Experimental and Analytical Study of Slender Reinforced Concrete Shear Wall under Cyclic In-Plane Lateral Load. Mathematical Problems in Engineering, 2017. https://doi.org/10.1155/2017/4020563