Abstract
Background/Objectives: Environmental contamination of dental surfaces is a major vector for cross-infection. Ultraviolet-C (UVC) irradiation provides rapid, chemical-free decontamination; however, depending on wavelength and ventilation conditions, ozone generation may occur. This study evaluated the germicidal efficacy of UVC on three high-touch surfaces: a wooden work table, a stainless-steel consumables table, and a dental unit table. Methods: Surfaces were sampled at baseline, after 5 min (27 mJ/cm2), and after 10 min (54 mJ/cm2) of UVC exposure at 90 µW/cm2. Colony-forming units (CFU/cm2) were enumerated using Mueller–Hinton agar. Results: UVC achieved >99% reduction after 5 min and complete elimination after 10 min. Material properties (porosity, reflectivity, and grooves), along with quantified parameters like surface roughness (Ra) and contact angle, influenced minor differences in decontamination. Conclusions: Used with appropriate safety protocols, short-duration UVC irradiation effectively decontaminates dental surfaces and can complement chemical disinfection. Future studies must incorporate artificially soiled surfaces, biofilms, and emerging far-UVC/UV-LED technologies.
Author supplied keywords
Cite
CITATION STYLE
Tsolak, S., Bud, E., Bucur, S. M., Păcurar, M., Man, A., & Manuc, D. (2025). Efficacy of UVC Radiation in Reducing Bacterial Load on Dental Office Surfaces. Dentistry Journal, 13(12). https://doi.org/10.3390/dj13120596