Kelayakan Pemutus Tenaga 150 KV Berdasarkan Uji Tahanan Isolasi Dan Tahanan Kontak

  • Rezyan R
  • Arnisa Stefanie
N/ACitations
Citations of this article
32Readers
Mendeley users who have this article in their library.

Abstract

Pemutus tenaga merupakan komponen yang sangat penting dalam infrastruktur sistem tenaga listrik yang membutuhkan pengujian tahanan isolasi dan tahanan kontak guna menjamin kinerjanya yang aman dan efektif. Tujuan dari penelitian ini adalah untuk menilai keberhasilan pemutus tenaga 150 kV dengan menggunakan uji tahanan isolasi dan tahanan kontak sebagai indikator. Metode pengumpulan data meliputi wawancara dengan pakar, telaah literatur, serta observasi langsung terhadap pemutus tenaga yang sedang diuji. Pengujian tahanan isolasi dilakukan dengan menggunakan alat pengujian isolasi, sementara untuk tahanan kontak digunakan alat uji MOM 690. Hasil penelitian menunjukkan bahwa nilai tahanan isolasi dan tahanan kontak dari pemutus tenaga 150 kV memenuhi standar yang ditetapkan oleh pabrikan. Dianjurkan untuk menjadwalkan pengujian secara berkala guna memastikan bahwa peralatan tetap berfungsi dengan baik. Keberadaan pengujian tahanan isolasi dan tahanan kontak dalam memelihara kinerja yang aman dan efektif dari pemutus tenaga juga ditekankan dalam penelitian ini. Dengan demikian, penelitian ini memberikan pemahaman yang komprehensif tentang pentingnya pengujian tahanan isolasi dan tahanan kontak untuk menjaga keandalan pemutus tenaga serta mencegah potensi kerusakan dan kecelakaan yang mungkin terjadi.The circuit breaker is a crucial component in the electric power system infrastructure that requires insulation resistance and contact resistance testing to ensure its safe and effective performance. The purpose of this research is to assess the success of a 150 kV circuit breaker using insulation resistance and contact resistance tests as indicators. Data collection methods include expert interviews, literature review, and direct observation of the tested circuit breaker. Insulation resistance testing is conducted using insulation testing equipment, while contact resistance is measured using an MOM 690 test device. The research results indicate that the insulation resistance and contact resistance values of the 150 kV circuit breaker meet the standards set by the manufacturer. It is recommended to schedule periodic testing to ensure that the equipment continues to function properly. The importance of insulation resistance and contact resistance testing in maintaining the safe and effective performance of the circuit breaker is also emphasized in this study. Therefore, this research provides a comprehensive understanding of the importance of insulation resistance and contact resistance testing in maintaining the reliability of circuit breakers and preventing potential damage and accidents.

Cite

CITATION STYLE

APA

Rezyan, R. F., & Arnisa Stefanie. (2024). Kelayakan Pemutus Tenaga 150 KV Berdasarkan Uji Tahanan Isolasi Dan Tahanan Kontak. EPIC Journal of Electrical Power Instrumentation and Control, 7(1), 42–50. https://doi.org/10.32493/epic.v7i1.39120

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free