In order to study the influence on gap changing of the static and dynamic components in axial flow pump, the axial flow pump model (TJ04-ZL-06) that used in the eastern of south-to-north water diversion project was selected. Steady turbulence field with different gaps was simulated by standard κ- turbulence model and double-time stepping methods. Information on the pressure distribution and velocity distribution of impeller surfaces were obtained. Then, calculated results were compared with the test results and analyzed. The results show that the performance of pump is not sensitive with the axial gap width under design conditions and the large flow rate condition. With increasing gap width, it will be improved in low flow rate condition. The attack angle of impeller inlet in small flow rate condition become small and the flow separation phenomenon can be observed in this condition. The axial velocity distribution of impeller outlet is nonlinear and to increase the axial gap is to improve the flow pattern near the hub effectively. The trend of calculating results is identical with test. It will play a guiding role to the axial pump operation and design in south-to-north water diversion project. © Published under licence by IOP Publishing Ltd.
CITATION STYLE
Wang, W. J., Liang, Q. H., Wang, Y., Yang, Y., Yin, G., & Shi, X. X. (2013). Performance analysis of axial flow pump on gap changing between impeller and guide vane. In IOP Conference Series: Materials Science and Engineering (Vol. 52). https://doi.org/10.1088/1757-899X/52/3/032011