Abstract
Twin-fluid atomizers underwent a significant development during the last few decades. They are common in many industrial applications such as fuel spraying, melt atomization and food processing. This paper is focused on the evaluation of four different twin-fluid atomizers. The aim is to compare the quality of sprays generated by various atomizers with similar dimensions and in the same operating regimes. A phase- Doppler anemometry (PDA) and particle image velocimetry (PIV) were used to measure spray characteristics such as velocity and size of the droplets. Measured data were used to compare droplet size distribution and to evaluate steadiness of the spray. Visualisations were made to support measured data and to clarify the principles of primary atomization and its influence on the spray.
Cite
CITATION STYLE
Zaremba, M., Mlkvik, M., Malý, M., Jedelský, J., & Jícha, M. (2015). Evaluation of Steadiness and Drop Size Distribution in Sprays Generated by Different Twin-Fluid Atomizers. In EPJ Web of Conferences (Vol. 92). EDP Sciences. https://doi.org/10.1051/epjconf/20159202118
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.