Abstract
Endobronchial valves (EBVs) are increasingly deployed in the management of severe emphysema. Initial studies focussed on volume reduction as the mechanism, with subsequent improvement in forced expiratory volume in 1 s (FEV1). More recent studies have emphasized importance of perfusion on predicting outcomes, though findings have been inconsistent. Gallium- 68 ventilation–perfusion (V/Q) photon emission tomography (PET)/computed tomography (CT) is a novel imaging modality with advantages in spatial resolution, quantitation, and speed over conventional V/Q scintigraphy. We report a pilot case in which V/Q-PET/CT demonstrated discordant findings compared with quantitative CT analysis, and directed left lower lobe EBV placement. The patient experienced a significant improvement in 6-min walk distance (6MWD) without change in spirometry. Post-EBV V/Q-PET/CT demonstrated a marked decrease in unmatched (detrimental) V/Q areas and improvement in overall V/Q matching on post-EBV V/QPET/ CT. These preliminary novel findings suggest that EBVs improve V/Q matching and may explain the observed functional improvements.
Author supplied keywords
Cite
CITATION STYLE
Leong, P., Roux, P. Y. L., Callahan, J., Siva, S., Hofman, M. S., & Steinfort, D. P. (2017). Reduced ventilation–perfusion (V/Q) mismatch following endobronchial valve insertion demonstrated by gallium-68 V/Q photon emission tomography/computed tomography. Respirology Case Reports, 5(5). https://doi.org/10.1002/rcr2.253