Detecting the misuse of 7-oxo-DHEA by means of carbon isotope ratio mass spectrometry in doping control analysis

9Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Rationale: The misuse of 7-oxo-DHEA (3β-hydroxyandrost-5-ene-7,17-dione) is prohibited according to the World Anti-Doping Agency (WADA) code. Nevertheless, it is easily available as a dietary supplement and from black market sources. In two recent doping control samples, significant amounts of its main metabolite 7β-OH-DHEA were identified, necessitating further investigations. Methods: As both 7-oxo-DHEA and 7β-OH-DHEA are endogenously produced steroids and no concentration thresholds applicable to routine doping controls exist, the development and validation of a carbon isotope ratio (CIR) mass spectrometry method ha been desirable. Excretion studies encompassing 7-oxo-DHEA, 7-oxo-DHEA-acetate, and in-house deuterated 7-oxo-DHEA were conducted and evaluated with regard to urinary CIR and potential new metabolites of 7-oxo-DHEA. Results: Numerous urinary metabolites were identified, some of which have not been reported before, while others corroborate earlier findings on the metabolism of 7-oxo-DHEA. The CIRs of both 7-oxo-DHEA and 7β-OH-DHEA were significantly influenced for more than 50 h after a single oral dose of 100 mg, and a novel metabolite (5α-androstane-3β,7β-diol-17-one) was found to prolong this detection time window by approximately 25 h. Applying the validated method to routine doping control specimens presenting atypically high urinary 7β-OH-DHEA levels clearly demonstrated the exogenous origin of 7-oxo-DHEA and 7β-OH-DHEA. Conclusions: As established for other endogenously produced steroids such as testosterone, the CIR allows for a clear differentiation between endo- and exogenous sources of 7-oxo-DHEA and 7β-OH-DHEA. The novel metabolites detected after administration may help to improve the detection of 7-oxo-DHEA misuse and simplify its detection in doping control specimens.

Cite

CITATION STYLE

APA

Piper, T., Fusshöller, G., Geyer, H., Toboc, A., Dănilă, M. G., & Thevis, M. (2020). Detecting the misuse of 7-oxo-DHEA by means of carbon isotope ratio mass spectrometry in doping control analysis. Rapid Communications in Mass Spectrometry, 34(12). https://doi.org/10.1002/rcm.8776

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free