A multisite assessment of the quantitative capabilities of the Xpert MTB/RIF assay

112Citations
Citations of this article
180Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Rationale: The Xpert MTB/RIF is an automated molecular test for Mycobacterium tuberculosis that estimates bacterial burden by measuring the threshold-cycle (Ct) of its M. tuberculosis-specific real-time polymerase chain reaction. Bacterialburden is an important biomarker for disease severity, infection control risk, and response to therapy. Objectives: Evaluate bacterial load quantitation by Xpert MTB/RIF compared with conventional quantitative methods. Methods: Xpert MTB/RIF results we recompared with smear-microscopy, semiquantiative solid culture, and time-to-detection in liquid culture for 741 patients and 2,008 samples tested in a multisite clinical trial. An internal control real-time polymerase chain reaction was evaluated for its ability to identify inaccurate quantitative Xpert MTB/RIF results. Measurements and Main Results: Assays with an internal control Ct greater than 34 were likely to be inaccurately quantitated; this represented 15% of M. tuberculosis-positive tests. Excluding these, decreasing M. tuberculosis Ct was associated with increasing smear microscopy grade for smears of concentrated sputum pellets (r s = 20.77) and directly from sputum (r s = -0.71). A Ct cutoff of approximately 27.7 best predicted smear-positive status. The association between M. tuberculosis Ct and time-to-detection in liquid culture (r s = 0.68) andsemiquantitative colony counts (r s = -0.56)wasweaker than smear. Tests of paired same-patient sputum showed that highviscosity sputum samples contained x32 more M. tuberculosis than nonviscous samples. Comparisons between the grade of the acid-fast bacilli smear and Xpert MTB/RIF quantitative data across study sites enabled us to identify a site outlier inmicroscopy. Conclusions: Xpert MTB/RIF quantitation offers a new, standardized approach to measuring bacterial burden in the sputum of patients with tuberculosis.

Cite

CITATION STYLE

APA

Blakemore, R., Nabeta, P., Davidow, A. L., Vadwai, V., Tahirli, R., Munsamy, V., … Alland, D. (2011). A multisite assessment of the quantitative capabilities of the Xpert MTB/RIF assay. American Journal of Respiratory and Critical Care Medicine, 184(9), 1076–1084. https://doi.org/10.1164/rccm.201103-0536OC

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free