Radical cystectomy with W-shaped orthotopic ileal neobladder constructed with non-absorbable titanium staples-long term follow-up.

3Citations
Citations of this article
37Readers
Mendeley users who have this article in their library.

Abstract

We retrospectively assessed our experience with the W-shaped orthotopic ileal pouch, which was constructed with non-absorbable titanium staples. For these purpose, we discuss the results of bladder capacity, urinary continence and early and long-term postoperative complications. We included in the study 17 patients who underwent radical cystoprostatectomy followed by construction of an orthotopic W-shaped ileal pouch between October 2000 and November 2009. A 65-70 cm segment of ileum was isolated and prearranged into a W-configuration, leaving two 10 cm intact segments on both sides of the ileal fragment. In our technique we entirely anatomized all adjacent limbs in order to create a sphere-shaped pouch. The ureters were directly anastomized to both intact segments of the ileal division. All our patients underwent pouchscopy 6 months after operation and annually. Mean operative time for neobladder reconstruction and ureteral anastomoses was 87 ± 7.67 minutes. In one patient a leak from the ileo-ileal anastomosis was confirmed on the 3rd day after operation. In 2 cases unilateral stricture of the ureteral-neobladder anastomosis was documented. Staple lines were mostly covered with ileal mucosa after 6 months. The mean functional bladder capacity was 340 ± 27.6 mL and 375 ± 43.4 mL at 6 and 12 months, respectively. First-year daytime and nighttime continence was good and acceptable in 90% and 78% of patients, while it increased to 95% during the 2nd year. The long term follow-up shows that non-absorbable titanium staples can be safely used for creation of an orthotopic ileal neobladder. However, these data should be further validated in a larger series of patients.

Cite

CITATION STYLE

APA

Kravchick, S., Lobik, L., Paz, A., Stepnov, E., Ben-Dor, D., & Cytron, S. (2013). Radical cystectomy with W-shaped orthotopic ileal neobladder constructed with non-absorbable titanium staples-long term follow-up. International Braz j Urol : Official Journal of the Brazilian Society of Urology, 39(2), 167–172. https://doi.org/10.1590/s1677-5538.ibju.2013.02.03

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free