Computer-aided diagnosis for optical diagnosis of diminutive colorectal polyps including sessile serrated lesions: A real-time comparison with screening endoscopists

45Citations
Citations of this article
35Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background We aimed to compare the accuracy of the optical diagnosis of diminutive colorectal polyps, including sessile serrated lesions (SSLs), between a computer-aided diagnosis (CADx) system and endoscopists during real-time colonoscopy. Methods We developed the POLyp Artificial Recognition (POLAR) system, which was capable of performing real-time characterization of diminutive colorectal polyps. For pretraining, the Microsoft-COCO dataset with over 300000 nonpolyp object images was used. For training, eight hospitals prospectively collected 2637 annotated images from 1339 polyps (i.e. publicly available online POLAR database). For clinical validation, POLAR was tested during colonoscopy in patients with a positive fecal immunochemical test (FIT), and compared with the performance of 20 endoscopists from eight hospitals. Endoscopists were blinded to the POLAR output. Primary outcome was the comparison of accuracy of the optical diagnosis of diminutive colorectal polyps between POLAR and endoscopists (neoplastic [adenomas and SSLs] versus non-neoplastic [hyperplastic polyps]). Histopathology served as the reference standard. Results During clinical validation, 423 diminutive polyps detected in 194 FIT-positive individuals were included for analysis (300 adenomas, 41 SSLs, 82 hyperplastic polyps). POLAR distinguished neoplastic from non-neoplastic lesions with 79% accuracy, 89% sensitivity, and 38% specificity. The endoscopists achieved 83% accuracy, 92% sensitivity, and 44% specificity. The optical diagnosis accuracy between POLAR and endoscopists was not significantly different (P =0.10). The proportion of polyps in which POLAR was able to provide an optical diagnosis was 98% (i.e. success rate). Conclusions We developed a CADx system that differentiated neoplastic from non-neoplastic diminutive polyps during endoscopy, with an accuracy comparable to that of screening endoscopists and near-perfect success rate.

Cite

CITATION STYLE

APA

Houwen, B. B. S. L., Hazewinkel, Y., Giotis, I., Vleugels, J. L. A., Mostafavi, N. S., Van Putten, P., … Dekker, E. (2022). Computer-aided diagnosis for optical diagnosis of diminutive colorectal polyps including sessile serrated lesions: A real-time comparison with screening endoscopists. Endoscopy, 55(8), 756–765. https://doi.org/10.1055/a-2009-3990

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free