Back to Basics: Endotracheal Tube Too Deep, Too Shallow, Then Just Right

  • Ganti L
  • Shivdat J
  • Bawany S
N/ACitations
Citations of this article
16Readers
Mendeley users who have this article in their library.

Abstract

We present a case of a 62-year-old who required intubation for the increased work of breathing secondary to a chronic obstructive pulmonary disease (COPD) exacerbation. The case illustrates the correct positioning of the endotracheal tube, as verified radiographically. It clearly depicts the tube that is initially advanced too far, then pulled back too much, and is finally in the correct position.

Cite

CITATION STYLE

APA

Ganti, L., Shivdat, J., & Bawany, S. (2018). Back to Basics: Endotracheal Tube Too Deep, Too Shallow, Then Just Right. Cureus. https://doi.org/10.7759/cureus.2706