Evaluation of radiation attenuation properties on a various composition of polydimethylsiloxane (PDMS) for fabrication of kidney phantom

12Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Chemical compounds such as polydimethylsiloxane (PDMS) and hydrogen silicone (HS) have been extensively used for fabricating medical phantoms due to its human tissue equivalency. This study aimed to evaluate the mass attenuation coefficient, effective atomic number, and other radiation attenuation properties of various polydimethylsiloxane samples and to verify the best material that can be used to simulate the kidney tissue. There are six samples of polymers in total, which are denoted as S0, S1, S2, S3, S4 and S5; these were 20/0/0, 16/4/0, 16/0/4, 12/4/4, 10/4/6 and 8/4/8, respectively with the composition of PDMS, HS and water. The Photon Shielding and Dosimetry (Phy-X/PSD) software (Phy-x.net) were used to estimate the attenuation properties, and the results were compared with the theoretical values obtained from the XCOM platform. The values of effective atomic number, mass attenuation coefficient, and linear attenuation coefficient, for PDMS S0 are reported to be the highest compared to all other samples, as S0 is based on 100% PDMS without any water and HS. The S1 sample, which only contained 20% of HS, was found to be higher than S2 sample, which had 20% water but without any HS. Hence, the water in samples significantly influences the radiation attenuation properties for photon energy. The Zeff for soft tissue and PDMS are different; their respective atomic numbers differ due to a presence of higher elements such as Si. This study reveals that the modified material, S1 samples constructed from 80% PDMS and 20% hydrophilic can be used to simulate the kidney in terms of the total mass attenuation coefficient, CT number and effective atomic number.

Cite

CITATION STYLE

APA

Kamal, I., Karim, M. K. A., Harun, H. H., Abdul Razak, H. R., Jian, L. Y., Chyi, J. L. Y., & Kechik, M. M. A. (2021). Evaluation of radiation attenuation properties on a various composition of polydimethylsiloxane (PDMS) for fabrication of kidney phantom. Radiation Physics and Chemistry, 189. https://doi.org/10.1016/j.radphyschem.2021.109661

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free