Response of an ultrasonically excited bubble near a fixed rigid object

5Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Various independent studies suggest that echo-contrast agents can increase the likelihood of ultrasonic bioeffects. To better understand bioeffects involving cavitation, a two-dimensional boundary element model was used to simulate ultrasonically excited bubble behavior near a rigid object, either a plane, sphere, or disk, the approximate size of a red blood cell. As the distance between the object and bubble increases, the bubble collapse becomes more spherically symmetric, producing higher maximum bubble pressures. Pressure and velocity fields around a bubble collapsing near a rigid disk are compared for two distances, demonstrating differences between more spherically symmetric and asymmetric bubble collapses. © 2005 Acoustical Society of America.

Cite

CITATION STYLE

APA

Miao, H., & Gracewski, S. M. (2005). Response of an ultrasonically excited bubble near a fixed rigid object. Acoustic Research Letters Online, 6(3), 144–150. https://doi.org/10.1121/1.1898344