Determination of the optimal atrioventricular delay in DDD pacing. Comparison between echo and peak endocardial acceleration measurements

202Citations
Citations of this article
57Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The goal of this study was to compare two methods determining the optimal atrioventicular delay (AVD) in 19 patients implanted with the BEST-Living\Rsystem for complete heart block. The definition of the optimal AVD was: the AVD with the echo method that provided the longest diastolic filling time without interruption of the A wave, and the AVD with the peak endocardial acceleration (PEA) method, corresponding to the knee of the PEA curve vs AV delay. The amplitude of the PEA was measured for every AVD programmed via an automatic scanner in steps of 60 to 300ms (40ms steps): in the VDD pacing mode with a low base rate, to obtain 100% sensed P waves; in DDD with a base rate=sinus rate+20%, to obtain 100% paced P waves. Echocardiographic (Echo) measurement of the left ventricular filling time were performed in the same AV delay settings in VDD and DDD as the ones tested in the PEA method, which were manually programmed. The optimal AVDs obtained in DDD and those obtained in VDD were compared in the echo and the PEA tests by a paired Student's t-test. The optimal AVDs obtained by both Echo and by PEA were also compared by a paired Student's t-test in VDD and DDD. The r value of the correlation between the optimal AVDs obtained by Echo and those obtained by PEA was calculated. Similar values of optimal AVD were obtained with both methods. The optimal AVDs given by the Echo technique (179±25ms in DDD and 124±18ms in VDD) were slightly, but significantly shorter than the ones obtained with the PEA method (202±21ms in DDD and 145±18ms in VDD, P<0·05). A highly significant difference between AVD VDD and AVD DDD was found with both methods (P<0·001). The correlation between the AVDs obtained with the echo and the PEA methods was highly significant (r=0·78, P<0·01). Pacemaker software could be modified to determine automatically the optimal AVDs to be applied throughout the heart rate range. © 1999 The European Society of Cardiology.

Cite

CITATION STYLE

APA

Ritter, P., Padeletti, L., Gillio-Meina, L., & Gaggini, G. (1999). Determination of the optimal atrioventricular delay in DDD pacing. Comparison between echo and peak endocardial acceleration measurements. Europace, 1(2), 126–130. https://doi.org/10.1053/eupc.1998.0032

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free