Radiation Dose Reduction in Preprocedural CT Imaging for TAVI/TAVR Using a Novel 3-Phase Protocol: A Single Institution's Experience

14Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose  To retrospectively investigate the effectiveness of a novel 3-phase protocol for computed tomography (CT) before transcatheter aortic valve implantation/transcatheter aortic valve replacement (TAVI/TAVR) in terms of radiation dose and image quality. Materials and Methods  A total of 107 nonrandomized patients (81 ± 7.4 years) scheduled for TAVI/TAVR underwent preprocedural CT on an 80-row CT scanner. 55 patients underwent a combined ECG-synchronized spiral scan of the chest and non-ECG-synchronized spiral scan of the abdomen/pelvis as recommended by the Society of Cardiovascular Computed Tomography (SCCT). 52 patients underwent an updated 3-phase variable helical pitch (vHP3) protocol combining a non-ECG-synchronized spiral scan of the upper thoracic aperture, followed by a prospective ECG-synchronized spiral scan of the heart, and a non-ECG-synchronized abdominal/pelvic spiral scan. The radiation dose was determined from an automatically generated protocol based on the CT dose index (CTDI). Objective image quality in terms of vessel attenuation and image noise was measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was evaluated using a 4-point scale and compared for interrater agreement using Cohen's weighted kappa coefficient (κw). All data were compared and statistically analyzed. Results  Use of the novel 3-phase vHP3 protocol reduced the dose-length product (DLP) from 1256.58 ± 619.05 mGy*cm to 790.90 ± 238.15 mGy*cm, reducing the effective dose (E) from 21.36 ± 10.52 mSv to 13.44 ± 4.05 mSv and size-specific dose estimates (SSDE) from 20.85 ± 7.29 mGy to 13.84 ± 2.94 mGy (p < 0.001). There were no significant differences in objective and subjective image quality between the two protocols and between the two readers. Conclusion  The novel 3-phase vHP3 protocol significantly reduces the radiation dose of preprocedural TAVI/TAVR CT without a loss of image quality. Key Points:   The use of a novel 3-phase protocol for preprocedural TAVI/TAVR CT reduces radiation dose by 37 % compared to a combined ECG-synchronized and non-ECG-synchronized spiral CT protocol. Objective image quality remains unaffected as image noise, SNR, and CNR did not differ significantly between the two protocols. The average attenuation of the aortic root and abdominal aorta exceeded 450 HU in both protocols. The average subjective image quality ratings were good to excellent for both protocols with almost perfect to substantial interrater agreement. Citation Format Shnayien S, Bressem KK, Beetz NL et al. Radiation Dose Reduction in Preprocedural CT Imaging for TAVI/TAVR Using a Novel 3-Phase Protocol: A Single Institution's Experience. Fortschr Röntgenstr 2020; 192: 1174 - 1182.

Cite

CITATION STYLE

APA

Shnayien, S., Bressem, K. K., Beetz, N. L., Asbach, P., Hamm, B., & Niehues, S. M. (2020). Radiation Dose Reduction in Preprocedural CT Imaging for TAVI/TAVR Using a Novel 3-Phase Protocol: A Single Institution’s Experience. RoFo Fortschritte Auf Dem Gebiet Der Rontgenstrahlen Und Der Bildgebenden Verfahren, 192(12), 1174–1182. https://doi.org/10.1055/a-1150-7646

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free