Comparison of 99mTc-MIBI scintigraphy, ultrasound, and mammography for the diagnosis of BI-RADS 4 category lesions

16Citations
Citations of this article
45Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: We sought to determine the diagnostic efficacy of Breast-specific gamma imaging (BSGI) in Chinese women with BI-RADS 4 category lesions and to compare this efficacy to that of ultrasound/mammography. Methods: We retrospectively analyzed data from 177 women that had undergone BSGI of BI-RADS 4 category lesions originally detected via ultrasound and/or mammography. Results: Of these 177 cases, 117 (66.1%) were malignant lesions and 60 (33.9%) were benign. The sensitivity, specificity, positive predictive values, and negative predictive values of BSGI were 94.9% (111/117), 78.3% (47/60), 89.5% (111/124), and 88.7% (47/53), respectively. The specificity and positive predictive values for mammography were 48.3% (29/60) and 77.5% (107/138), while for ultrasound they were 53.3% (32/60) and 79.6% (109/137), respectively. The sensitivity and specificity of BSGI for the detection of lesions ≤1 cm in size were 90.9% (10/11) and 88.0% (22/25), respectively, while for breast lesions >1 cm in size these values were 94.3% (100/106) and 71.4% (25/35), respectively. In addition, BSGI sensitivity and specificity values for dense breast tissue were 94.0% (79/84) and 78.0% (39/50), respectively, whereas for non-dense breast tissue these vales were 97.0% (32/33) and 80.0% (8/10), respectively. The sensitivity of BSGI for invasive ductal carcinomas (IDC) and ductal carcinomas in situ (DCIS) was 98.9% (95/96) and 75.0% (9/12), respectively. The tumor to normal tissue ratio of BSGI for malignant lesions was significantly higher than for benign lesions (2.18 ± 1.17 vs 1.66 ± 0.40, t = 7.56, P<0.05). Conclusions: These results indicate that BSGI is highly sensitive for the detection of such lesions, achieving good positive/negative predictive values. This suggests that for IDC in particular, BSGI is superior to ultrasound and mammography for the diagnosis of BI-RADS 4 category lesions, although this was less apparent for the diagnosis of DCIS lesions. BSGI exhibited excellent performance in dense breast tissue and for the detection of lesions ≤1 cm in size.

Cite

CITATION STYLE

APA

Liu, H., Zhan, H., & Sun, D. (2020). Comparison of 99mTc-MIBI scintigraphy, ultrasound, and mammography for the diagnosis of BI-RADS 4 category lesions. BMC Cancer, 20(1). https://doi.org/10.1186/s12885-020-06938-7

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free