A method for determining the polarization state of the metal with the middle potential in order to calculate the corrosion rate of multi-metals complicated galvanic couple

10Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

Abstract

A method based on the mixed potential theory is put forward to determine the polarization state of the metal with the middle potential in tri-metals galvanic couple. The potential distribution and current density distribution of the complicated galvanic couple composed of AA5083, 20# steel, and H62 copper alloy were simulated by finite element method, and the effect of configuration position on the complicated galvanic corrosion behavior was studied, which was verified by the galvanic current measurement. The results of experiment and numerical simulation match well, indicating that the method to determine the polarization state of the metal with the middle potential is reliable, which provides the reference to modeling multi-metals complicated galvanic corrosion.

Cite

CITATION STYLE

APA

Hu, Q. F., Zhang, T., Geng, S. J., & Wang, F. H. (2017). A method for determining the polarization state of the metal with the middle potential in order to calculate the corrosion rate of multi-metals complicated galvanic couple. Materials and Corrosion, 68(9), 935–942. https://doi.org/10.1002/maco.201609358