Influence of lens fluorescence on fluorescence lifetime imaging ophthalmoscopy (Flio) fundus imaging and strategies for its compensation

8Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose: To explore the contribution of crystalline lens fluorescence to fluorescence lifetimes measured with fluorescence lifetime imaging ophthalmoscopy (FLIO) and to propose a computational model to reduce the lens influence. Methods: FLIO, which detects autofluorescence decay over time in a short-wavelength spectral channel (SSC, 498–560 nm) and a long-wavelength spectral channel (LSC, 560–720 nm), was performed on 32 patients before and after cataract extraction. The mean autofluorescence lifetime (τm) of the fundus was determined from a threeexponential fit of the postoperative fluorescence decays. The preoperative measurements were fit with series of exponential functions in which one fluorescence component was time-shifted in order to represent lens fluorescence. Results: Postoperatively, τm was 185 ± 22 ps in the SSC and 209 ± 34 ps in the LSC at the posterior pole. These values were best reproduced by fitting the postoperative measurements with a three-exponential model with a time-shifted third fluorescence component (SSC, 203 ± 45 ps; LSC, 215 ± 29 ps), whereas disregarding time-shifted lens fluorescence resulted in significantly (P < 0.001) longer τm values (SSC, 474 ± 206 ps; LSC, 215 ± 29 ps). The fluorescence of the cataract lens contributed to the total fluorescence by 54.2 ± 10.6% (SSC) and 29.5 ± 9.9% (LSC). Conclusions: Cataract lens fluorescence greatly alters fluorescence lifetimes measured at the fundus by FLIO, resulting in an overestimation of the lifetimes; however, this may be compensated for considerably by taking lens influence into account in the fitting model. Translational Relevance: This study investigates cataract fluorescence in FLIO and a mathematical model for compensation of this influence.

Cite

CITATION STYLE

APA

Brauer, J. L., Schultz, R., Klemm, M., & Hammer, M. (2020). Influence of lens fluorescence on fluorescence lifetime imaging ophthalmoscopy (Flio) fundus imaging and strategies for its compensation. Translational Vision Science and Technology, 9(8), 1–10. https://doi.org/10.1167/TVST.9.8.13

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free