Gonioreflectometer for measuring 3D spectral BRDF of horizontally aligned samples with traceability to SI

14Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Present article describes a 3D gonioreflectometer developed at Aalto University for the measurement of spectral bidirectional reflectance distribution function (sBRDF) of horizontally aligned samples, needed to study sBRDF of sand from satellite calibration test sites. The new set-up incorporates three motorized arms that allow to measure in- and out-of-plane sBRDF. Illumination of the sample is provided by a supercontinuum laser coupled with laser line tunable filters and detection is performed with two types of photodiodes (Si and InGaAs) enabling collection of sBRDF in the spectral range from 450 nm to 1700 nm. The instrument is operated in the relative mode and its traceability to SI is achieved with the help of a 2D absolute reference gonioreflectometer available at Aalto University. The calibration procedure as well as system's uncertainty estimation are described. The performance of the 3D gonioreflectometer is validated by measurements of a ceramic diffuse reflectance sample.

References Powered by Scopus

Directional reflectance and emissivity of an opaque surface

664Citations
N/AReaders
Get full text

RadCalNet: A radiometric calibration network for earth observing imagers operating in the visible to shortwave infrared spectral range

175Citations
N/AReaders
Get full text

An Evaluation of the Use of Atmospheric and BRDF Correction to Standardize Landsat Data

122Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Development of primary reference facilities and measurement comparison of standard artifacts for the bidirectional transmittance distribution function

7Citations
N/AReaders
Get full text

Infrared BRDF measurement based on projection reconstruction with attenuated aperture filter effects

4Citations
N/AReaders
Get full text

MSL goniospectrophotometer measurement model

3Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Lanevski, D., Manoocheri, F., & Ikonen, E. (2022). Gonioreflectometer for measuring 3D spectral BRDF of horizontally aligned samples with traceability to SI. Metrologia, 59(2). https://doi.org/10.1088/1681-7575/ac55a7

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 3

75%

Lecturer / Post doc 1

25%

Readers' Discipline

Tooltip

Physics and Astronomy 3

75%

Engineering 1

25%

Save time finding and organizing research with Mendeley

Sign up for free