In-line Pullout Strength of 2 Acetabular Fixation Methods for Ligamentum Teres Reconstruction of the Hip: A Cadaveric Study

2Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Ligamentum teres (LT) reconstruction is an appropriate alternative in select cases of LT full-thickness tears, resulting in hip micro- or macroinstability. Graft fixation at the acetabular fossa is critical to achieving the best functional results. Purpose: The purpose of this study is to compare the pullout strength of 2 graft fixation methods used for LT reconstruction of the hip. Study Design: Controlled laboratory study. Methods: In 7 cadaveric specimens, the acetabular socket was prepared after the native LT was transected and the femoral head was removed. Seven separate tibialis anterior grafts were then prepared by suturing a running-locking No. 2 suture on each tail of the graft. Three specimens had fixation of the graft to the acetabulum using an adjustable cortical suspension suture button; the remaining 4 were fixed to the acetabulum using a knotless suture anchor. Specimens were then mounted onto a custom jig within a mechanical test frame to allow for the in-line pull of the graft fixation construct. After a preload of 5 N, each specimen was loaded to failure at 0.5 mm/s. Stiffness and load to failure were measured for each specimen construct. Results: Suture button fixation had a higher mean load to failure when compared with the knotless anchor fixation method (mean ± SD, 438.1 ± 114.3 vs 195.9 ± 50.0 N; P =.01). There was no significant difference in mean stiffness between the methods of fixation (24.5 ± 1.4 vs 26.5 ± 5.8 N/mm; P =.6). Conclusion: In this cadaveric study, the suture button fixation demonstrated greater load to failure than the knotless anchor fixation. Clinical Relevance: Results of this study can guide surgical decision making when selecting an acetabular fixation method for LT reconstruction.

Cite

CITATION STYLE

APA

Lall, A. C., Ankem, H. K., Ryan, M. K., Beason, D. P., Diulus, S. C., Roach, R. P., … Domb, B. G. (2021). In-line Pullout Strength of 2 Acetabular Fixation Methods for Ligamentum Teres Reconstruction of the Hip: A Cadaveric Study. Orthopaedic Journal of Sports Medicine, 9(12). https://doi.org/10.1177/23259671211052533

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free