Plasma C5 glucose-to- 2H 2O ratio does not provide an accurate assessment of gluconeogenesis during hyperinsulinemic-euglycemic clamps in either nondiabetic or diabetic humans

7Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

OBJECTIVE-Measurement of plasma C2 glucose enrichment is cumbersome. Therefore, the plasma C5 glucose-to- 2H 2O rather than the plasma C5-to-C2 glucose ratio commonly has been used to measure gluconeogenesis and glycogenolysis during hyperinsulinemic-euglycemic clamps. The validity of this approach is unknown. RESEARCH DESIGN AND METHODS-Ten nondiabetic and 10 diabetic subjects ingested 2H 2O the evening before study. The following morning, insulin was infused at a rate of 0.6 mU • kg -1 • min -1 and glucose was clamped at ∼5.3 mmol/l for 5 h. Plasma C5 glucose, C2 glucose, and 2H 2O enrichments were measured hourly from 2 h onward. RESULTS-Plasma C2 glucose and plasma 2H 2O enrichment were equal in both groups before the clamp, resulting in equivalent estimates of gluconeogenesis and glycogenolysis. In contrast, plasma C2 glucose and plasma C5 glucose enrichments fell throughout the clamp, whereas plasma 2H 2O enrichment remained unchanged. Since the C5 glucose concentration and, hence, the C5 glucose-to- 2H 2O ratio is influenced by both gluconeogenesis and glucose clearance, whereas the C5-to-C2 glucose ratio is only influenced by gluconeogenesis, the C5 glucose-to- 2H 2O ratio overestimated (P < 0.01) gluconeogenesis during the clamp. This resulted in biologically implausible negative (i.e., calculated rates of gluconeogenesis exceeding total endogenous glucose production) rates of glycogenolysis in both the nondiabetic and diabetic subjects. CONCLUSIONS-Plasma C5 glucose-to- 2H 2O ratio does not provide an accurate assessment of gluconeogenesis in nondiabetic or diabetic subjects during a traditional (i.e., 2-3 h) hyperinsulinemic-euglycemic clamp. The conclusions of studies that have used this approach need to be reevaluated. © 2008 by the American Diabetes Association.

Cite

CITATION STYLE

APA

Basu, R., Chandramouli, V., Dicke, B., Landau, B. R., & Rizza, R. A. (2008). Plasma C5 glucose-to- 2H 2O ratio does not provide an accurate assessment of gluconeogenesis during hyperinsulinemic-euglycemic clamps in either nondiabetic or diabetic humans. Diabetes, 57(7), 1800–1804. https://doi.org/10.2337/db08-0195

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free