Medtronic Freestyle aortic bioprosthesis: A potential option for haemodialysis patients

2Citations
Citations of this article
33Readers
Mendeley users who have this article in their library.

Abstract

OBJECTIVES End-stage renal disease patients on regular haemodialysis are at higher risk of calcification. Therefore, many surgeons have concerns regarding the implantation of bioprostheses in such patients. The haemodynamic advantages of stentless aortic bioprostheses support their use; however, these have not been studied yet in end-stage renal disease patients. We studied accordingly the early and mid-term outcomes of aortic valve replacement (AVR) using Medtronic Freestyle stentless aortic bioprostheses in this subset of patients in comparison with stented aortic bioprostheses. METHODS We retrospectively studied two groups of consecutive patients on regular haemodialysis who required AVR between 2007 and 2013. Non-Freestyle (NFS) group received stented aortic bioprostheses (36 patients) and Freestyle (FS) group received Medtronic Freestyle aortic bioprostheses (48 patients). Follow-up ranged from 2 to 76 months with a mean follow-up of 36.3 ± 25 months. RESULTS Patients in both groups showed similar demographic characters regarding age (76.4 ± 8.1 vs 74.9 ± 7.2 years; P = 0.35), male gender (58 vs 60%; P = 0.57) and diabetes mellitus (42 vs 48%; P = 0.57). Smaller aortic bioprostheses were implanted in the NFS (23.3 ± 1.2 vs 25.4 ± 2.1; P < 0.001) with consequently higher postoperative mean gradients (14.1 ± 4.1 vs 11.9 ± 5.3 mmHg; P = 0.004). No significant differences were noted regarding postoperative neurological disorder (8 vs 12%; P = 0.73), deep sternal wound infection (3 vs 4%; P = 0.68), re-exploration (8 vs 8%; P = 0.91) and in-hospital mortality (6 vs 4%; P = 0.92). Mid-term follow-up showed higher prosthetic valve calcification and/or sclerosis in NFS group (25 vs 6%; P = 0.015), whereas no significant differences were noticed between the two groups regarding stroke (0 vs 8%; P = 0.13), endocarditis (0 vs 4%; P = 0.50), 36- and 72-month survival (51 ± 2%, 14 ± 4% vs 55 ± 2%, 19 ± 3%, respectively; P = 0.45). CONCLUSIONS Aortic bioprostheses are a good option for haemodialysis patients requiring AVR, offering acceptable mid-term survival. The Medtronic Freestyle aortic bioprostheses could allow the implantation of larger bioprostheses inferring consequently lower mean gradients, with a potentially higher resistance to calcification and sclerosis in haemodialysis patients.

Cite

CITATION STYLE

APA

Hegazy, Y. Y., Rayan, A., Sodian, R., Hassanein, W., & Ennker, J. (2016). Medtronic Freestyle aortic bioprosthesis: A potential option for haemodialysis patients. Interactive Cardiovascular and Thoracic Surgery, 22(4), 459–464. https://doi.org/10.1093/icvts/ivv388

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free