Continuous glucose monitor metrics from five studies identify participants at risk for type 1 diabetes development

3Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims/hypothesis: We aimed to assess whether continuous glucose monitor (CGM) metrics can accurately predict stage 3 type 1 diabetes diagnosis in those with islet autoantibodies (AAb). Methods: Baseline CGM data were collected from participants with ≥1 positive AAb type from five studies: ASK (n=79), BDR (n=22), DAISY (n=18), DIPP (n=8) and TrialNet Pathway to Prevention (n=91). Median follow-up time was 2.6 years (quartiles: 1.5 to 3.6 years). A participant characteristics-only model, a CGM metrics-only model and a full model combining characteristics and CGM metrics were compared. Results: The full model achieved a numerically higher performance predictor estimate (C statistic=0.74; 95% CI 0.66, 0.81) for predicting stage 3 type 1 diabetes diagnosis compared with the characteristics-only model (C statistic=0.69; 95% CI 0.60, 0.77) and the CGM-only model (C statistic=0.68; 95% CI 0.61, 0.75). Greater percentage of time >7.8 mmol/l (p<0.001), HbA1c (p=0.02), having a first-degree relative with type 1 diabetes (p=0.02) and testing positive for IA-2 AAb (p<0.001) were associated with greater risk of type 1 diabetes diagnosis. Additionally, being male (p=0.06) and having a negative GAD AAb (p=0.09) were selected but not found to be significant. Participants classified as having low (n=79), medium (n=98) or high (n=41) risk of stage 3 type 1 diabetes diagnosis using the full model had a probability of developing symptomatic disease by 2 years of 5%, 13% and 48%, respectively. Conclusions/interpretation: CGM metrics can help predict disease progression and classify an individual’s risk of type 1 diabetes diagnosis in conjunction with other factors. CGM can also be used to better assess the risk of type 1 diabetes progression and define eligibility for potential prevention trials.

Cite

CITATION STYLE

APA

Calhoun, P., Spanbauer, C., Steck, A. K., Frohnert, B. I., Herman, M. A., Keymeulen, B., … Beck, R. W. (2025). Continuous glucose monitor metrics from five studies identify participants at risk for type 1 diabetes development. Diabetologia, 68(5), 930–939. https://doi.org/10.1007/s00125-025-06362-1

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free