Simultaneous determination of glucose and lactose in sour milk using an immobilized glucose oxidase electrode combined with a β-galactosidase-attached measuring cell

2Citations
Citations of this article
1Readers
Mendeley users who have this article in their library.

Abstract

Glucose and lactose in sour milk are simultaneously determined by the use of a glucose-sensing enzyme electrode combined with a measuring cell which contains a layer of immobilized β-galactosidase. The electrode current changes linearly with time from ca. 1 to a few min after the addition of a glucose/lactose mixture. The lactose content (70 µM~7 mM) is determined from the rate of current change in the linear region, and glucose content (5µM~1.5 mM) is determined by extrapolating the straight current/time line to t=0.40 min, and by measuring the intercept on the vertical (current) axis at t=0.40 min. R.S.D.-values in the 10 successive measurements of 0.3 mM glucose/3.0 mM lactose mixture are 2.4% for glucose and 3.9% for lactose. About 20 samples of sour milk can be analyzed per hour by the present electrode/cell system. © 1990, The Japan Society for Analytical Chemistry. All rights reserved.

Cite

CITATION STYLE

APA

Fumio, M., & Michihiko, A. (1990). Simultaneous determination of glucose and lactose in sour milk using an immobilized glucose oxidase electrode combined with a β-galactosidase-attached measuring cell. Bunseki Kagaku, 39(11), 729–734. https://doi.org/10.2116/bunsekikagaku.39.11_729