How does vacuum forming affect Pelite mechanical properties?

6Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

Pelite® is a polyethylene closed cell foam commonly used as an interface material in prosthetics. Both normal and vacuum-formed Pelite were tested under compression and under shear loading. For shear testing, the results were not significantly different for normal and vacuum-formed Pelite. For normal Pelite, the slope of the stress-strain curve was 1.17MPa (±0.14) while for vacuum-formed Pelite it was 1.24MPa (±0.22). Compressive results, however, were significantly different. Below 80kPa of applied compression, the slope of the stress-strain curve for normal Pelite was 0.99MPa (±0.11) while for vacuum formed Pelite it was 0.72MPa (±0.12). Between 80kPa and 200kPa of applied compression, the slope of the stress-strain curve for normal Pelite was 0.45MPa (±0.03) while for vacuum formed Pelite it was 0.55MPa (±0.05). Reasons for the differences and their significance to interface mechanics and computer-aided prosthesis design are discussed. © 1994, SAGE Publications. All rights reserved.

Cite

CITATION STYLE

APA

Sanders, J. E., & Daly, C. H. (1994). How does vacuum forming affect Pelite mechanical properties? Prosthetics and Orthotics International, 18(1), 43–48. https://doi.org/10.3109/03093649409164670