Electrophysiological findings during re-do procedures after single-shot pulmonary vein isolation for atrial fibrillation with pulsed field ablation

9Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Pulsed field ablation (PFA) is a novel ablation technology recently adopted in the treatment of atrial fibrillation (AF). Currently, little is known about the durability of PFA ablation lesions. Methods: We investigated patients who underwent redo-ablation due to recurrent AF/atrial-flutter or tachycardia (AFL/AT) following PVI with PFA. We report electrophysiological findings and ablation strategy during redo-ablation. Results: Of 447 patients undergoing index PVI with PFA, 14 patients (age: 61.9±10.8 years; 7 (50.0%) males; left atrial volume index (n=10): 39.4±14.6 mL/m2) were referred for redo-ablation. Initial indication was paroxysmal-AF in 7 patients, persistent-AF in 6 and long-standing-persistent-AF in one patient. Mean time-to-recurrence was 4.9±1.9 months. Three patients received additional posterior-wall-isolation during index PFA. Twelve (85.7%) patients suffered AF recurrence and 5/12 had concomitant AFL. In the remaining 2 patients, one had a (box-dependent) AFL, and one had an atypical AT. No patients had all PVs reconnected. Reconnection in zero, one, two or three PVs was found in 35.7%, 21.4%, 14.3%, and 28.6% of patients, respectively. All 7 patients with zero or one reconnection with AF recurrence received additional/repeat posterior-wall-isolation during re-ablation, while in the others, PVs were re-isolated. Patients with only AFL/AT had no reconnection of PVs, and the substrate was successfully ablated. Conclusions: Durable PVI (all PV’s isolated) was observed in over one-third of patients at re-do. The predominant recurrent arrhythmia following PVI-only was AF. Concomitant (35.7%) or isolated (14.3%) AFL/AT recurrence was observed in 50% of patients.

Cite

CITATION STYLE

APA

Magni, F. T., Scherr, D., Manninger, M., Sohns, C., Sommer, P., Hovakimyan, T., … Mulder, B. A. (2023). Electrophysiological findings during re-do procedures after single-shot pulmonary vein isolation for atrial fibrillation with pulsed field ablation. Journal of Interventional Cardiac Electrophysiology, 66(7), 1729–1737. https://doi.org/10.1007/s10840-023-01559-z

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free