Numerical calculation of circulating current losses in stator transposition bar of large hydro-generator

19Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

To reduce circulating current losses in stator strands of hydro-generator, strand transposition is widely used in stator bars. At present, the traditional analytical method for calculating circulating current losses cannot accurately simulate the distribution of leakage magnetic field, which will bring a large deviation to the calculation result and not benefit the winding design. The numerical calculation method for circulating current losses in stator bar is presented in this study, by which the leakage magnetic field distribution of stator transposition bar can be described in detail through establishing three-dimensional actual transposition model. The 0°/360°/0° transposition bar in a 180 MW hydro-generator is taken as an example and the circulating current losses in stator bar strands are calculated. The causes of errors in traditional analytical method are discussed through the comparison of the leakage magnetic field distribution obtained by numerical calculation method and traditional analytical method.

References Powered by Scopus

Transposition effects on bundle proximity losses in high-speed PM machines

84Citations
N/AReaders
Get full text

Transpositions in stator bars of large turbogenerators

63Citations
N/AReaders
Get full text

Circulating currents in stator coils of large turbine generators and loss reduction

62Citations
N/AReaders
Get full text

Cited by Powered by Scopus

A New Global Transposition Method of Stator Winding and Its Loss Calculation in AC Machines

22Citations
N/AReaders
Get full text

Derivation of Temperature Distribution of Stator Winding with Transposed Conductors for a Large Air-Cooled Hydrogenerator

16Citations
N/AReaders
Get full text

Numerical calculation and analysis of temperature field for stator transposition bar in hydro-generator

15Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Liang, Y., Bian, X., Yang, L., & Wu, L. (2015). Numerical calculation of circulating current losses in stator transposition bar of large hydro-generator. IET Science, Measurement and Technology, 9(4), 485–491. https://doi.org/10.1049/iet-smt.2014.0230

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 5

100%

Readers' Discipline

Tooltip

Engineering 4

80%

Environmental Science 1

20%

Save time finding and organizing research with Mendeley

Sign up for free