Added value of 3D ultrasound image-guided hepatic interventions by X matrix technology

2Citations
Citations of this article
3Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Image-guided hepatic interventions are integral to the management of infective and neoplastic liver lesions. Over the past decades, 2D US was used for guidance of hepatic interventions; with the recent advances in US technology, 3D US was used to guide the hepatic interventions. This study aimed to illustrate the added value of 3D image-guided hepatic interventions by X matrix technology. Methods: This prospective study was performed on 100 patients that were divided into two groups: group A which included 50 patients who were managed by using 2D US probe guidance, and group B which included 50 patients who were managed by using 3D X matrix US probe guidance. Thermal ablation was done for 70 patients; 40 radiofrequency ablation (RFA) (20 by the 2D probe and 20 by the 3D X matrix probe) and 30 microwave ablation (MWA) (15 by the 2D probe and 15 by the 3D X matrix probe). Chemical ablation (PEI) was done for 20 patients (ten by the 2D probe and ten by the 3D X matrix probe). Drainage of hepatic collections and biopsy from undiagnosed hepatic focal lesions were done for ten patients (five by the 2D probe and five by the 3D X matrix probe). Results: The efficacy of US-guided hepatic interventions by 3D X matrix probe was higher than the 2D probe but not significantly higher, with a p value of 0.705, 0.5428 for RFA and MWA, respectively, 0.5312 for PEI, and 0.2918 for drainage of hepatic collections and biopsy. The complications related to the use of the 3D X matrix probe were significantly lower than the 2D probe with a p value of 0.003. The timing of the procedure was shorter by the usage of a 3D X matrix probe in comparison with the 2D probe with a p value of 0.08, 0.34 for RFA and PEI and significantly shorter for MWA and drainage of hepatic collection, biopsy with a p value of 0.02, 0.001, respectively. Conclusions: 3D US-guided hepatic interventions by X matrix probe have better efficacy, less complication, and shorter time of procedure than the 2D US-guided hepatic interventions.

Cite

CITATION STYLE

APA

Omar, H., Korayem, E. M., Khalil, A. A. S., & Abokoura, S. (2023). Added value of 3D ultrasound image-guided hepatic interventions by X matrix technology. Egyptian Journal of Radiology and Nuclear Medicine, 54(1). https://doi.org/10.1186/s43055-023-01138-2

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free