High-temperature corrosion-fatigue behavior of ductile cast irons for exhaust manifolds applications

15Citations
Citations of this article
13Readers
Mendeley users who have this article in their library.

Abstract

In the present study, low-cycle fatigue (LCF) tests and oxidation tests in controlled atmospheres are carried out at 800 °C on two ductile cast irons SiMo51 and SiMo1000. The LCF tests are conducted in argon and synthetic exhaust gas, whereas oxidation tests are carried out in the latter atmosphere. S-N curves and weight-gain curves are presented. The crack growth mechanisms and oxidation mechanisms are investigated, as well as the synergetic effects. A surprising finding of increased fatigue resistance in oxidizing atmosphere is partly explained.

Cite

CITATION STYLE

APA

Xiang, S. M., Zhu, B. H., & Jonsson, S. (2018). High-temperature corrosion-fatigue behavior of ductile cast irons for exhaust manifolds applications. In Materials Science Forum (Vol. 925 MSF, pp. 369–376). Trans Tech Publications Ltd. https://doi.org/10.4028/www.scientific.net/MSF.925.369