Intra- and interlaboratory variability of paroxysmal nocturnal hemoglobinuria testing by flow cytometry following the 2012 Practical Guidelines for high-sensitivity paroxysmal nocturnal hemoglobinuria testing

29Citations
Citations of this article
35Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background Sutherland et al. recently published the Practical Guidelines for high-sensitivity detection of paroxysmal nocturnal hemoglobinuria (PNH) clones by flow cytometry (FCM), containing concise protocols for PNH testing. Methods Using this approach, we studied the intra- and interlaboratory variability observed in a multicenter study in which fresh blood samples containing three clinically relevant PNH clone sizes within the granulocytic, monocytic, and red blood cell (RBC) populations were shipped to each participating center. Results Coefficients of variation (CVs) for precision/reproducibility analysis ranged from 0.01%/0.02% to 0.48%/0.45% (big clone), from 0.69%/1.52% to 4.24%/5.80% (small-intermediate clone), from 1.47%/3.91% to 15.01% /17.83% (minor clone) for PNH white blood cells (WBCs) and from 0.24%/0.48% to 1.76%/1.83% (big clone), from 0.80%/1.14% to 2.39%/4.45% (small-intermediate clone), from 1.09%/3.36% to 10.54%/10.23% (minor clone) for PNH RBCs, respectively. Linear regression analysis showed excellent performance correlation between centers (r > 0.99), Wilcoxon rank test revealed no statistically significant differences for PNH granulocytes, monocytes, and RBCs (P > 0.05%), Bland-Altman analysis demonstrated good performance agreement for all target PNH clones (mean bias ranging from -1.47 to 0.71). Conclusion Our results demonstrate very good intra- and interlaboratory performance characteristics for both precision and reproducibility analyses and excellent correlation and agreement between centers for all target PNH clone sizes. Our data confirm the reliability and robustness of the recently published Practical Guidelines approach for high sensitivity PNH testing by flow cytometry and suggest that such an approach represents an excellent basis for standardization of PNH testing by flow cytometry. Copyright © 2013 International Clinical Cytometry Society.

Cite

CITATION STYLE

APA

Marinov, I., Kohoutová, M., Tkáčová, V., Lysák, D., Holubová, M., Stehlíková, O., … Illingworth, A. (2013). Intra- and interlaboratory variability of paroxysmal nocturnal hemoglobinuria testing by flow cytometry following the 2012 Practical Guidelines for high-sensitivity paroxysmal nocturnal hemoglobinuria testing. Cytometry Part B - Clinical Cytometry, 84(4), 229–236. https://doi.org/10.1002/cyto.b.21075

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free