Performance of a Non-Invasive System for Monitoring Blood Glucose Levels Based on Near-Infrared Spectroscopy Technology (Glucube®)

12Citations
Citations of this article
37Readers
Mendeley users who have this article in their library.

Abstract

Background: The need for frequent blood glucose (BG) monitoring and the inconveniences associated with self-monitoring of BG (SMBG) have driven the development of non-invasive approaches. Methods: This prospective study aimed to investigate the accuracy of glucose level calculation using the near-infrared spectroscopy (NIRS) technology Glucube® system. People with Type 1 diabetes, Type 2 diabetes, prediabetes, and normal glucose metabolism were included. Over one week, individuals performed glucose measurements with the Glucube® system and capillary blood fingersticks with a standard glucometer (Ascensia Contour® Next). To assess the impact of the improvement in dexterity, the accuracy variables were compared with the point-of-care (POC) glucometer Accu-Chek® Inform II in a one-week sub-study. Results: Overall, 105 subjects (mean age 53.8 ± 13.8 years, 50.5% female) participated, resulting in 1914 paired glucose measurements between 49 and 331 mg/dL. Total mean absolute relative difference (MARD) was 20.3%, MARD for values >100 mg/dL was 18.3%, and mean absolute deviation (MAD) for values <100 mg/dL was 24.9%. A total of 97.3% of measurements fell within A+B Parkes zones, and 58.8%, 76.9%, and 88.1% within +−20%, +−30%, or +−40% error, respectively. On completion, 62 participants (59%) fulfilled the one-week prospective sub-study. In this subgroup, the total MARD was reduced between day 1 and day 8 from 22.8 to 18.3% (p = 0.068). The percentages within Zone A were 51.6 vs. 61.2%, Zone B 46.8 vs. 33.9%, and Zone C 1.6 vs. 4.8%, and the sum of Parkes Zones A+B was 98.4 vs. 95.2% (p = 0.311) for day 1 and day 8, respectively. Conclusions: Glucube® is a novel non-invasive system based on NIRS technology for monitoring blood glucose levels. Its promising capabilities support further research.

Cite

CITATION STYLE

APA

Gómez-Peralta, F., Luque Romero, L. G., Puppo-Moreno, A., & Riesgo, J. (2024). Performance of a Non-Invasive System for Monitoring Blood Glucose Levels Based on Near-Infrared Spectroscopy Technology (Glucube®). Sensors, 24(23). https://doi.org/10.3390/s24237811

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free