Reverse osmosis as one-step wastewater treatment: A case study on groundwater pollution

10Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.

Abstract

The present case study is focused on performance evaluation of a Reverse Osmosis (RO) membrane based pilot plant to treat the ground/surface drinking water sources polluted by flood, rivers and/or canals. The RO plant was designed, fabricated and then operated with polluted water. Two feed water samples having a TDS of 2.000 mg · L-1 and 10.000 mg · L-1 respectively, were taken and analyzed for physical, chemical and microbiological contaminants. The RO plant was run once through over a span of 100 hrs at an operating pressure of 15 bar. TDS rejections were found to be more than 94% while permeate flux was measured to be 25.82 L · m-2 · hr-1 to 40.55 L · m-2 · hr-1. Results show that RO plant has a potential to remove physical, chemical and microbiological contaminants like Total Coliform and E. Coli in one step.

Cite

CITATION STYLE

APA

Ali, W., Ur Rehman, W., Younas, M., Ahmad, M. I., & Gul, S. (2015). Reverse osmosis as one-step wastewater treatment: A case study on groundwater pollution. Polish Journal of Chemical Technology, 17(4), 42–48. https://doi.org/10.1515/pjct-2015-0067