Complement to standard method for measuring normal incidence sound transmission loss with three microphones

  • Salissou Y
  • Panneton R
  • Doutres O
58Citations
Citations of this article
56Readers
Mendeley users who have this article in their library.

Abstract

Complement to standard E2611-09 of the American Society for Testing and Materials [Standard Test Method for Measurement of Normal Incidence Sound Transmission of Acoustical Materials Based on the Transfer Matrix Method (American Society for Testing and Materials, New York, 2009)] is proposed in order to measure normal incidence sound transmission loss of materials in a modified impedance tube using a three-microphone two-load or one-load method. The modified tube is a standard two-microphone impedance tube, where a third microphone is mounted on a movable hard termination. This method is conceptually identical to the four-microphone two-load or one-load method described in the standard; however, it requires fewer transfer functions and one microphone less. The method is validated on (1) symmetrical homogeneous and (2) non-symmetrical non-homogeneous specimens.

Cite

CITATION STYLE

APA

Salissou, Y., Panneton, R., & Doutres, O. (2012). Complement to standard method for measuring normal incidence sound transmission loss with three microphones. The Journal of the Acoustical Society of America, 131(3), EL216–EL222. https://doi.org/10.1121/1.3681016