Noninvasive evaluation of renal tissue oxygenation with blood oxygen level-dependent magnetic resonance imaging early after transplantation has a limited predictive value for the delayed graft function

5Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

Abstract

Purpose: The aim of this study was to evaluate the feasibility of renal oxygenation assessment using blood oxygen level-dependent (BOLD) magnetic resonance imaging (MRI) in the early period after kidney transplantation and to estimate its prognostic value for delayed graft function. Material and methods: Examinations were performed in 50 subjects: 40 patients within a week after the kidney transplantation and 10 healthy controls, using T2*-weighted sequence. Measurements in transplant patients were correlated to basic laboratory parameters in the early period after transplantation and at follow-up. Results: Examinations of seven patients (18%) were rejected due to their poor technical quality. Mean R2* values in transplant recipients were lower than in controls (11.6 vs. 15.9 Hz; p = 0.0001). An R2* value of 0.28 Hz was calculated as the minimal detectable change. There was no relation between R2* values and laboratory parameters. However, patients eGFR ≥ 40 ml/min/1.73 m2 presented higher R2* values than recipients eGFR < 40 ml/min/1.73 m2 (12.0 vs. 11.1 Hz; p = 0.0189). In ROC analysis R2* of ≤ 11.7 predicted an early reduced graft function with 0.82 sensitivity and 56% specificity (AUC = 0.708; p = 0.024) but was not useful for delayed graft function prediction (p > 0.7). Conclusions: Evaluation of renal graft oxygenation using BOLD MRI is technically challenging in the early period after transplantation. An R2* value of 0.28 Hz may in practice be considered as the minimal detectable change. The delayed graft function seems not to be dependent on early oxygenation values. Further, large-scale studies are necessary to confirm the latter observation.

Cite

CITATION STYLE

APA

Sławińska, A., Serafin, Z., Zawada, E., Białecki, M., Wypych, K., Woderska, A., … Włodarczyk, Z. (2018). Noninvasive evaluation of renal tissue oxygenation with blood oxygen level-dependent magnetic resonance imaging early after transplantation has a limited predictive value for the delayed graft function. Polish Journal of Radiology, 83, e389–e393. https://doi.org/10.5114/pjr.2018.78622

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free