Abdominal aorta measurements by a handheld ultrasound device compared with a conventional cart-based ultrasound machine

12Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.
Get full text

Abstract

BACKGROUND: Ultraportable or pocket handheld ultrasound devices (HUD) may be useful for large-scale abdominal aortic aneurysm screening. However, the reproducibility of measurements has not been compared with conventional cart-based ultrasound machines. OBJECTIVES: Investigate the intra- and inter-operator reproducibility of a HUD compared with a conventional ultrasound machine for aortic screening. ESIGN: Analytical, cross-sectional. SETTING: Ultrasound department at a large tertiary care hospital in Riyadh. PATIENTS AND METHODS: Eligible male participants aged ≥60 years were invited to participate upon arriving for a non-vascular ultrasound appointment. Three repeated anteroposterior measurements of the transverse aorta were made at the proximal and distal locations for each machine before repeating the measurements on a subset of participants by a second blinded operator. Intraclass correlation coefficients (ICC) and the Bland-Altman method were used to analyze reproducibility. MAIN OUTCOME MEASURE: Inter-system and intra- and inter-operator ICCs. SAMPLE SIZE: 114 males with repeated measurements by second operator on a subset of 35 participants. RESULTS: The median age (interquartile range) of participants was 68 years (62-74 years). The intra- and inter-operator ICCs were all >0.800 showing almost perfect agreement except for the inter-operator reproducibility at the proximal location using a conventional machine (ICC= 0.583, P=.007) and the Butterfly device (ICC=0.467, P=.037). The intersystem ICCs (95% CI) were 0.818 (0.736-0.874) and 0.879 (0.799-0.924) at the proximal and distal locations, respectively. The mean difference in aortic measurement between the ultrasound systems was 0.3 mm (1.7%) in the proximal location and 0.6 mm (3.6%) in the distal location. In total, >91% of the difference in measurements between the machines was <3 mm. The mean scanning time was 4:16 minutes for the conventional system and 3:53 minutes for the HUD (P=.34). CONCLUSIONS: Abdominal aortic screening using a HUD was feasible and reliable compared with a conventional ultrasound machine. A pocket HUD should be considered for large-scale screening. LIMITATIONS: No cases of abdominal aortic aneurysm in the sample and lack of blinding. CONFLICT OF INTEREST: None.

Cite

CITATION STYLE

APA

Alfuraih, A. M., Alrashed, A. I., Almazyad, S. O., & Alsaadi, M. J. (2021). Abdominal aorta measurements by a handheld ultrasound device compared with a conventional cart-based ultrasound machine. Annals of Saudi Medicine, 41(6), 376–382. https://doi.org/10.5144/0256-4947.2021.376

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free